GE T SFP CISCO vs CISCO 您所在的位置:网站首页 cisco method GE T SFP CISCO vs CISCO

GE T SFP CISCO vs CISCO

#GE T SFP CISCO vs CISCO| 来源: 网络整理| 查看: 265

hi,

i've received a mix of plastic (bright yellow) and metal (gold) GE T SFPs and used them on ASR1001-x.

the 'CISCO' SFP on ASR-2 works perfect but i got the link between ASR-1 and N3K switch UP using 'CISCO-METHODE' after hardcoding negotation, speed, and duplex settings BUT getting a very small increment CRC errors on the N3K side.

there's no CRC errors on the ASR1side

 

ASR-1#sh int g0/0/1GigabitEthernet0/0/1 is up, line protocol is up   Hardware is BUILT-IN-2T+6X1GE, address is 00fc.bab6.1234 (bia 00fc.bab6.1234)

  Description: Eth1/11  Internet address is 1.2.3.4/27  MTU 1500 bytes, BW 100000 Kbit/sec, DLY 10 usec,      reliability 255/255, txload 157/255, rxload 158/255  Encapsulation ARPA, loopback not set  Keepalive not supported   Full Duplex, 1000Mbps, link type is force-up, media type is T  output flow-control is on, input flow-control is on  ARP type: ARPA, ARP Timeout 04:00:00  Last input 00:00:00, output 00:00:03, output hang never  Last clearing of "show interface" counters 3w0d  Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0  Queueing strategy: fifo  Output queue: 0/40 (size/max)  30 second input rate 61984000 bits/sec, 13460 packets/sec  30 second output rate 61955000 bits/sec, 13435 packets/sec     462652296 packets input, 254086241871 bytes, 0 no buffer     Received 11533 broadcasts (0 IP multicasts)     0 runts, 0 giants, 0 throttles      0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored     0 watchdog, 110382 multicast, 0 pause input     460940740 packets output, 253736175337 bytes, 0 underruns     0 output errors, 0 collisions, 2 interface resets     2260 unknown protocol drops     0 babbles, 0 late collision, 0 deferred     0 lost carrier, 0 no carrier, 0 pause output

 

N3K-1# sh int e1/11Ethernet1/11 is up Dedicated Interface   Hardware: 10/100/1000 Ethernet, address: e4c7.22c0.1234 (bia e4c7.22c0.1234)  Description: ASR1  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec  reliability 255/255, txload 1/255, rxload 1/255  Encapsulation ARPA  Port mode is access  full-duplex, 1000 Mb/s  Beacon is turned off  Input flow-control is off, output flow-control is off  Switchport monitor is off   EtherType is 0x8100   Last link flapped 11:50:25  Last clearing of "show interface" counters 02:04:28  0 interface resets  30 seconds input rate 53631800 bits/sec, 12170 packets/sec  30 seconds output rate 53666984 bits/sec, 12201 packets/sec  Load-Interval #2: 5 minute (300 seconds)    input rate 51.96 Mbps, 11.87 Kpps; output rate 51.99 Mbps, 11.90 Kpps  RX    93094489 unicast packets  8285 multicast packets  3110 broadcast packets    93105996 input packets  50908204410 bytes    0 jumbo packets  0 storm suppression bytes    0 runts  0 giants  112 CRC  0 no buffer    112 input error  0 short frame  0 overrun   0 underrun  0 ignored    0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop    0 input with dribble  0 input discard    0 Rx pause  TX    93284129 unicast packets  18482 multicast packets  1818 broadcast packets    93304429 output packets  50937193987 bytes    0 jumbo packets    0 output errors  0 collision  0 deferred  0 late collision    0 lost carrier  0 no carrier  0 babble 0 output discard    0 Tx pause

 

 

i'm unable to remove the SFP since it's in a production and only able to issue 'sh hw-module transceiver' commands. cable and SFP were already swapped and suspect i got a bad batch of SFP or third party ones.

 

can someone advise if there's compatibility issue on GE T SFP between ASR and N3K?

is CISCO-METHODE a non-genuine SFP?

how can i tell without removing from the chassis? any other show commads i can use?

 

ASR-1#sh hw-module int g0/0/1 transceiver idprom brief

IDPROM for transceiver GigabitEthernet0/0/1:

  Description                               = SFP or SFP+ optics (type 3)

  Transceiver Type:                         = GE T (26)

  Product Identifier (PID)                  = SP7041-E       

  Vendor Revision                           = E  

  Serial Number (SN)                        = MTC18291234   

  Vendor Name                               = CISCO-METHODE  

  Vendor OUI (IEEE company ID)              = 00.00.00 (0)

  CLEI code                                 = N/A      

  Cisco part number                         = N/A      

  Device State                              = Enabled.

  Date code (yy/mm/dd)                      = 14/07/21

  Connector type                            = Unknown.

  Encoding                                  = 8B10B

                                              NRZ

  Nominal bitrate                           = GE (1300 Mbits/s)

  Minimum bit rate as % of nominal bit rate = not specified

  Maximum bit rate as % of nominal bit rate = not specified

 

 

ASR-2#sh hw-module int g0/0/1 transceiver idprom brief

IDPROM for transceiver GigabitEthernet0/0/1:

  Description                               = SFP or SFP+ optics (type 3)

  Transceiver Type:                         = GE T (26)

  Product Identifier (PID)                  = SP7041-TE      

  Vendor Revision                           = A1 

  Serial Number (SN)                        = MTC21214567  

  Vendor Name                               = CISCO          

  Vendor OUI (IEEE company ID)              = 00.17.05 (5893)

  CLEI code                                 = CMUIAGBCAA

  Cisco part number                         = 30-1475-01

  Device State                              = Enabled.

  Date code (yy/mm/dd)                      = 17/06/07

  Connector type                            = Unknown.

  Encoding                                  = 8B10B

                                              NRZ

  Nominal bitrate                           = GE (1300 Mbits/s)

  Minimum bit rate as % of nominal bit rate = not specified

  Maximum bit rate as % of nominal bit rate = not specified



【本文地址】

公司简介

联系我们

今日新闻

    推荐新闻

    专题文章
      CopyRight 2018-2019 实验室设备网 版权所有